水利防汛抗旱论文 摘要:本文介绍了减压井的水利防汛抗旱论文工作原理,减压效果,以及设计参数的水利防汛抗旱论文选取,并通过对减压井的主要设计参数(井距、贯入度及井径)的正交试验,分析了其主要设计参数对减压效果的显著性影响水平,提出了减压井的合理布置方法,以供实际工程设计参考。 关键词:堤坝 减压井 设计参数 正交试验
Studies on the Application for Relief-well in Eliminating and Pressure-reducing of Embank
Chen Changsheng Chen Yunmei
(School of Water Resources and Hydropower, Wuhan University, HuBei Water Resource Research Institution, Wuhan City 430072, China)
Abstract:This paper introduced the relief-well’s work principle, pressure-reducing effects and the choice of its design parameters. Through the orthogonal experiment of main design parameters such as, distance, penetration and diameter of relief-well, analyzing the influence of these parameters to the effect of pressure reducing, and proposing a reasonable layout method of relief-well. The result can be useful for the design of actual project.
Key words: embank; relief-well; design parameters; orthogonal experiment.
1 减压井及其工作原理
对下游设置铺盖的大坝或者有天然弱透水覆盖层堤防,常由于铺盖和覆盖层的透水性较下层土为小,使位于堤坝下游下卧砂层压力水头过大,以致地基覆盖层渗透坡降超标,发生严重渗透变形,影响堤坝安全,同时导致堤坝下游沼泽化,恶化居住条件和作物生长条件。减压井导渗原理是:通过滤水管将来自上游渗透水流直接导入井内,阻止水流往下游流动,在地下迅速降低压力水头,以达到保护大坝的稳定和降低下游地下水位的目的。因此,大坝或堤防下游设置排渗减压井可达到以下三个目的:1)避免坝址下游发生渗透破坏;2)避免坝址下游沼泽化;3)降低坝体浸润线,增加坝体稳定性。
2 减压井设计
减压井的设计主要是依据堤坝运行的标准、坝基地质和土层结构特性等,确定减压井的类型、井深、井径、井距、井口高程、井系轴线位置以及反滤层,充分发挥减压井的作用,降低工程造价。
2.1 减压井类型的选择
减压井可分为浅井、深井两类。浅井是挖穿不透水或相对隔水的覆盖土层,把井底置于透水层上部的减压井。这种透水层厚度不大、埋深较浅的地基能起良好的减压排渗作用,井距一般较小,虽占地较多但仍较经济。深井是井孔深入大部或全部透水层的减压井。当井孔部分深入透水层,称不完整井。当井孔深入全部透水层,称完整井。对于深厚透水层的地基,采用深井效果最明显。对于不均匀透水地基,井孔应贯穿不透水夹层或相对隔水层,采用完整井或深孔不完整井。
|