| | 化工论文 免费小论文 Maximum permissible error of heat meter in operation 摘要 分析了热量表的化工论文 免费小论文误差组成及影响误差的化工论文 免费小论文因素,并模拟计算了实际不同运行工况下热量表的最大误差,得出结论;当散热器进出水温差Δt达到最小值、流量q达到最小允许值时,热表误差限的最大值为10%,随流量的增加,误差限逐渐降为8%;Δt不变时,流量较小误差较小;q不变时,Δt越大,误差越小,当Δt>3Δt min时,误差接近常数;一定温差下,当实际流量大于常用流量的一半后,误差近似为常数。 关键词:热量表/最大允许误差/供热计量收费 Abstract Analyses the constitution of the heat meter measurement error and its affecting factors, calculates the maximal measurement error of a heat meter under the different operation conditions. Concludes that the maximal measurement error of heat meter is 10% when the temperature difference between inlet and outlet fluid of a radiator is minimal and the flow rate is also minimal admissible. When flow rate(q) increases, the error limits will gradually reduce to 8%. For a constant Δt , the smaller the error. When Δt>3Δt min, the error will be close to a constant. For certain temperature differences, when the actual flow rate q is larger than half of common flow rate the error is nearly a constant. Keywords:heat meter/ maximum permissible error/ heat billing 供热计量收费中,热量表计量是否准确,不仅关系到用户的利益,而且也关系到供热公司的利益。因此,用户和供热公司都希望能准确计量。而计量的误差大小,不仅和热量表的准确度有关,而且和实际运行工况有着密切的关系。 1 热量表准确度 1.1 准确度定义 用相误差限E来定义热量表的准确度[1,2]: (1) 式中: Vd为热量表的显示值;Vc为真值。 1.2 误差限的计算 以目前常用的3级准确度的热量表为例,其相对误差限E的计算公式为[1,2]: E=E C + E t + E q (2) (3) (4) (5) 式中E C , E t , E q--分别为计算器、配对温度传感器、流量传感器误差限; Δt min--散热器进、出口水最小温差,在此温差下,热量表准确度不应超过误差限; Δt--散热器进、出口水温差; qp--常用流量,即供暖系统正常连续运行时水的流量,在此流量下,热量表准确度不应超过误差限;同时,无论在何种情况下流量传感器的误差限量最大不能超过5%。; q--通过散热器的流量。 把(3),(4),(5)代入式(2),得: (6) 式中 Ect为计算器与配对温度传感器误差限之和,其值与温差成反比;Eq为流量传感器误差限,其值与流量成反比。
| | | |