给水排水工程考研论文 摘要:介绍了新沂市城市污水处理厂的给水排水工程考研论文污泥膨胀情况。经过调查分析,最后确认污泥膨胀是由微量金属元素缺乏所致。为此,采取了向配水井、贮泥池内投加微量元素混合液的给水排水工程考研论文措施,从而解决了污泥膨胀的问题。 关键词:污泥膨胀 污泥负荷 微量金属元素 SVI
Control of Sludge Bulking in Xinyi City Wastewater Treatment Plant Zhanglingfeng Zhouxinmin (`Xinyi City Wastewater Treatment Plant, Xinyi ,Jiangsu, 221400, China)
Abstract: This paper introduces the problem of sludge bulking in Xinyi city wastewater treatment plant. Through investigation analysis it is confirmed finally that trace metal element lacks to cause the sludge bulking .Therefore throw to add trace element to match well and store mud pool, so the problem of sludge bulking is solved. Key words: Sludge bulking; Mud load; Trace metal element; SVI
1.污水处理厂概况
新沂市城市污水处理厂采用三槽式氧化沟处理工艺(处理规模为首期3×104 kg/d),其污泥负荷为0.050 kg-BOD/(kgMLSS·d),MLSS为4142mg/L,污泥龄为22d ,氧化沟水力停留时间4h,污泥含水率为82%,贮泥池污泥浓度为10.5mg/L,滤液污泥浓度为6.0mg/L.2003年1月经验收后正式运行,其进、出水的水质见表1。
表1 污水厂的进、出水水质
|