中级职称给排水论文 摘要:膜的中级职称给排水论文优越的中级职称给排水论文分离特性,使膜滤技术在饮用水生产时也受到越来越广的应用。本实验采用了日本引进的优质聚乙烯中空纤维滤膜,在周家渡水厂,嵊山水厂和内野毛巾厂进行实用性研究。结果表明:处理砂滤水和混凝沉淀水时,在滤压损失为0-2m水柱范围内,膜滤装置处理能力20-30L/m2/h,处理后的水浊度在0.1NTU以下;细菌指标能达到国家标准。但在直接过滤原水时,膜阻力增加很快,浊度也增大。研究显示该装置能有效代替部分净水工艺生产自来水。 关键词:聚乙烯中空纤维膜 全量过滤 饮用水 低浊度 病原菌
A PrototyPe Study for Membrane Filtration Technology in an attempt to produce potable water Ju Suwei Cheng Mengen Enji Iwamura (Shanghai Ebara Engineering & Services Co.,Ltd. 200071)
Abstract: The usage of membrane filtration technology is growing very rapidly worldwide to produce potable water. The research have been performed, in: ZhouJiaDu Waterworks, Shenghai Uchino Towel Co., Ltd., in use of high quality hollow fiber polyethylene membrane made in Japan. The outcome of the research is summarized as: with pressure drop of 0~2mH2O, filtration performance is proved as 20~30lit/m2/h,turbidity of the respective filtrate is below 0.1NTU; Pathogenic bacteria count is below the national requlation. This unit can economically replace a major protion of the conventional water purification process in drinking-water production. Key words: polyethylene hollow fiber membrane, dead end filtration, Drinking-water, low turbidity, pathogenic bacteria.
1 序论
膜滤技术在饮用水生产时可根据进水的水质而选用合适的膜,得到的处理水水质容易控制,卫生安全性好,所以正受到越来越广的应用。近年来,自来水生饮的一些欧美国家及日本仍有寄生性病原体感染的事例发生。美国Wiscosin州的Milwaukee在1993年Oregon州的Jackson County在1992年发生过感染,还出现了死亡病例。英国的Isie of thaunet area在1990年发生过感染。日本神奈川县的平口市在1994年琦玉县的越生町在1996年也发生过感染。这些国家都在一些地区建设采用膜滤技术的自来水厂,即使水源受到污染时也能保证供水安全。现在,日产1万吨以上的水厂在美国有42家,欧洲有33家,日本全国的膜滤制水能力达400多万吨。在我国用膜滤技术生产饮用水的还仅限于瓶装和拥装水行业。这次研究中采用了日本引进的优质聚乙烯中空纤维滤膜,在周家渡水厂,嵊山水厂和内野毛巾厂结合部分处理工艺对砂滤后水和混凝沉淀水进行实验,同时还对一些原水进行直接膜滤处理进行了尝试。
|