基础排水论文 摘要:针对经典的基础排水论文污水处理生化工艺的基础排水论文缺陷,提出用超滤膜作载体的生物接触氧化处理工艺。试验结果证明:经初沉处理后的生活污水,当接触时间为3 h左右时,CODCr、BOD5、SS和NH3-N的去除率分别可达到83%、92%、94%和60%左右。理论分析亦表明此法在污水生物处理方面前景良好。 关键词:污水处理 充氧 中空纤维膜 生物膜 载体
中图分类号:X703 文献标识码:A 文章编号:1000-4602(2000)08-0004-04
Study on Biological Contact Oxidation Process with Ultrafiltration Membrane as Carrier
LIU Guan yi (Depart.of Civil Eng.,Hebei Institute of Sci.and Tech.,Tangshan 063009,China)
Abstract:In view of defect of classical biochemical wastewater treatment process, a contact oxidation process with ultrafiltration membrane as carrier was developed. Experimental results demonstrated that when treating primary settled domestic wastewater with contact time of about 3h, the removal efficiencies of CODCr、BOD5、SS and NH3-N were 83%, 92%, 94% and 60% respectively. The theoretical analysis also showed that this process would have good prospects in biological wastewater treatment. Keywords:wastewater treatment;aeration;hollow fiber membrane;biofilm;carrier
用好氧微生物处理污水的一个关键环节是要保证有足够的氧气供微生物氧化水中的有机物。为保证氧气供应,一般采用向污水中充氧的方法。生物膜在氧化有机物的过程中,由于溶解氧的浓度梯度方向与有机物的浓度梯度方向一致,造成生物膜的底部出现厌氧层,导致生物膜脱落而混入处理水中。因此,要设二沉池进行膜水分离。 若想获得一种高效、经济、紧凑的生化处理系统,关键是找出一个能“静静”地将氧气溶解到水中的方法,而微孔膜和选择性透气膜材料的出现与推广使得解决这个关键问题成为可能,这就是所谓的无泡充氧法。无泡充氧法即用疏水性的微孔膜或选择性透气膜材料将液、气两相相互隔离,根据Henry定律,气体可借助于气、液间的分压差透过微孔之间的气、液界面或选择性透气膜而溶入或溶出液体。这一过程中没有肉眼可见的气泡产生,氧气自然也可借此充入水中完成充氧过程。 根据上述分析,笔者设计了一个将反应器与沉淀池合并的试验装置,进行了污水净化试验。
|