给水排水 毕业小论文 摘要:本研究采用混凝超滤联用处理工艺对淮河水进行了中试试验。结果表明,膜出水浊度低于0.5NTU,CODMn低于3mg/L,色度为5度,氨氮低于0.5mg/L,均低于同期常规处理出水指标。超滤膜运行一个多月,膜压差增长缓慢。 关键词:淮河水 超滤 混凝 膜压差
Ultrafiltration of Huaihe River water source combined with coagulation treatment LI Jing-hua1 LU Yu-zhu2 DONG Bing-zhi3 CAO Da-wen3 XIONG Yi3 XU Qiang1 FUN Jin-chu3 (1.Huainan Public Burear, 2.Huainan Water Save Office, Anhui Huainan 232007; 3.School of Environmental Science and Engineering, Tongji University, Shanghai 200092)
Abstract:Ultrafiltration of Huaihe River water source combined with coagulation treatment with pilot-scale experiment was conducted. Thw results show that turbidity,CODMn, color and ammonia-nitrogen of membrane treated were below 3mg/L,5 and below 0.5mg/L respectively, all of which were below those traditional process treated. The transmembrane pressure increased slowly during more than one month of running. Key words:Huaihe River water source, Ultrafiltration, coagulation, transmembrane pressure
1 前言
淮南市的给水排水 毕业小论文主要饮用水水源的给水排水 毕业小论文淮河由于水资源量不足,同时又受到工农业以及生活污水的污染,导致饮用水水质严重恶化,特别是上游开闸排污时,由于工业污水的集中排放,饮用水水质问题尤其突出,给淮南市人民生活造成严重影响。由于目前自来水厂采用传统处理工艺无法有效地去除水中有机物,因此,必须寻求新的处理饮用水处理方法。 膜分离法代表2l世纪饮用水技术发展方向,具有占地面积小,出水水质好,自动化程度高等特点11l。由于超滤膜截留分子量较大,无法去除水中的溶解性有机物,故本研究采用混凝和超滤膜联用技术对淮河水进行试验。
2 试验方法与装置
2.1 水质 中试试验期间的淮河水(淮南段)主要水质指标如下表所示。 2.2 试验装置 选择混凝+预处理+UF膜作为中试处理工艺。工艺中各处理单元的作用为: ·混凝:将水中大部分的悬浮固体和部分有机物通过混凝形成微絮凝体; ·砂滤:截留混凝形成的絮凝体,去除水中大部分的悬浮固体和大分子有机物,提高膜通量; ·UF膜:截留水中微小絮凝体,去除水中残留的悬浮固体和有机物,进一步提高水质。
表1 淮河水主要水质指标
|