给水排水 评职论文 摘要:正压式二氧化氯发生器是为了解决自来水管网、深井泵后、油井注水管道等带压场合投加消毒剂的给水排水 评职论文需要而开发出的给水排水 评职论文新型发生 。目前大多数正压式二氧化氯发生器所采用的仍然是 NaClO3+HCl的化学法反应工艺,该反应工艺是产生 ClO2和Cl2的过程。从化学平衡角度分析,压力增加会抑制正向反应的进行。为了验证实际效果是否如此,本文通过在不同压力下对正压式反应器 ClO2产量、纯度、得率及总有效氯 产量等指标进行测定与比较得出,在 0~0.6M Pa的常用压力下,压力的变化对二氧化氯发生器的产气效率无显著影响。 关键词:正压式 二氧化氯发生器 压力影响 消毒
The Effect of Pressure to Aerogenesis Efficiency of Chlorine Dioxide Generator Lin Xinjie, Zhu Dacheng, Bao Xunxiang, He Qihuan (Dept. Of Environmental Science & Engineering of Nanjing University of Science & Technology, Nanjing 210094)
Abstract With determining and comparing the result of the output of chlorine dioxide, the purity of chlorine dioxide, the rate of chlorine dioxide, the capacity of active chlorine and the output of chlorine generated by positive pressure type chlorine dioxide generator under different pressure, this paper draws the conclusion that the effect of pressure to aerogenesis efficiency of chlorine dioxide generator is indistinctive when the pressure is in the range of 0~0.6M Pa. Keyword positive pressure type chlorine dioxide generator the effect of pressure disinfection
二氧化氯以其优良的水处理特性已得到业内人士的普遍认可,并在饮用水、工业循环冷却水、废水治理、水产养殖用水等领域得以广泛应用。随着ClO2应用技术的不断发展,国内ClO2发生装置也不断地更新换代,推陈出新。从早期的自循环式、负压直投式到现今的正压式发生设备。 正压式二氧化氯发生器是近两年才开发出的主要用于深井泵后、自来水管网、油井注水管道等在线带压加药的新型消毒设备。采用NaClO3+HCl反应工艺的正压式ClO2发生器其化学法反应过程中产生ClO2和Cl2气体。从化学平衡理论上分析压力的增加会抑制这两种气体的生成,从而降低ClO2的产量,影响消毒效果。为了验证实际情况是否如此,本实验采用国内具有一定代表性的正压式ClO2发生器的核心部件“华浦CPF-100C型反应器”进行加压试验,并取得一定结果,希望该试验结果能对正压式ClO2发生器的使用者和生产者有一定的参考价值。
|