给水排水工程论文 摘要:广州市城市污水具有有机物浓度低,碳、氮、磷比不合理的给水排水工程论文特点.采用序批式活性污泥法工艺对广州地区城市污水进行了实验研究.结果表明:在污泥负荷为0.14~0.26kg[BOD5]/(kg[MLSS])时,出水BOD5为5.12~13.6 mg/L,CODCr浓度为10.7~32.2 mg/L,NH3-N为2.83~9.23 mg/L,TP为0.1~0.45mg/L,证明了采用SBR工艺处理碳氮比较低的给水排水工程论文城市污水是可行的. 关键词:城市污水 污水处理 SBR
中图分类号:X799.3 文献标识码:A 文章编号:1009-2455(2002)02-0018-03
Test Research on the Municcipal Wastewater Treatment Using Sequencing Batch Reactor ZHANG Ke-fang, Zhang Chao-sheng, Fang Qian, WU Xiao-jun, ZHOU Li-ping, TAN Xiao-ping (Municipal and Environmental Department of Civil Engineering Academy, Guangzhou University, Guangzhou 510405, China)
Abstract: Guangzhou municipal wastewater contains low organic matters and C, N and P ratios are not fitting for conventional biological treatment. A sequencing batch reactor(SBR)process was tested in municipal wastewater treatment. When sludge loading was0.14-0.26kg[BOD5]/(kg[MLSS].d), the indices of effluent from SBR were as follows:BOD5=5.12~13.6mg/L, CODCr=10.7~32.2mg/L, NH3-N=2.83~9.23mg/L and TP=0.1~0.45mg/L. The result shows that using SBR to treat municipal wastewater with low content carbon and nitrogen is applicable. Key words: municipal wastewater; wastewater treatment; sequencing batch reactor
引言
在城市污水处理中,由于地理环境和气候因素的影响,广州城市污水水质有明显区别于北方城市污水水质的特点,一般北方地区城市污水BOD5在100~200mg/L之间,NH3-N在20~30mg/L之间,TP在2~7mg/L之间,而广州地区城市污水BOD5在40~80mg/L之间,NH3-N在20~30mg/L之间,TP在1~7mg/L之间,即有机物浓度低,碳、氮、磷比例不合理。所以开发研究适合广州地区城市污水特点的简单、高效的污水处理工艺流程,是当务之急。 本实验研究采用SBR艺,处理广州地区的城市污水,达到了在一个反应装置内既去除有机物又能脱氮除磷,而且磷的出水指标达到了0.1~0.45mg/L,这样的结果目前国内外还未见类似的报道。
1 实验装置与方法
1.1 实验装置及水质 SBR反应器由有机玻璃制成。总容积47.4L,有效容积42.8L。采用空压机曝气,穿孔管布气。其流程见图1。

试验所用的污水前期是在实验室配水,后期则取自广州市某河涌城市污水。反应器中污泥是从广州市大坦沙污水厂所取,然后进行培养驯化。试验污水水质见表1,试验运行方式见表2。 表1 试验污水水质 mg.L-1
|