中级职称给排水论文 摘要:采用由惰性和活性滤料(由极性和非极性滤料复合而成)复合构成的中级职称给排水论文新型生物活性滤料滤池进行过滤试验。结果表明,该滤池对氨氮的中级职称给排水论文去除率>90%,对CODMn的去除率>40%,使Ames试验致突变性降低约1/3左右,其出水水质满足国家《生活饮用水卫生标准》(GB 5749—85),具有较好的处理效果。 关键词:复合生物活性滤料 生物滤池 给水处理
中图分类号:TU991.24文献标识码:A 文章编号:1000-4602(2001)12-0001-05
Study on the Characteristics of Biofilter with Composite Active Medium ZHONG Li-juan1,ZHU Ming-zhang1,LI Wei1,GU Yu-bing1,YAO Yu-lin2,ZHAO You-shi2
(1.Chengdu City General Water Supply Co.,Chengdu 610072,China; 2.School of Urban Construction and Environmental Engineering,Chongqing University,Chongqing 400045,China)
Abstract:Test was made for the new type biofilter composed of inactive and active medium (polar and non-polar medium).Test results show that in the filter,removal rate of NH3-N and CODMn is>90% and 40% respectively,so that the mutation rate arising from Ames test is decreased by about 1/3.The effluent quality can meet the national standard 《Sanitary Standard for Drinking Water》(GB 5749—85),with better treatment efficiency being achieved. Keywords:composite bioactive medium;biofilter;water treatment
以沙河为水源的水厂,其制水能力约占成都市自来水公司总制水能力的40%,但随着城市的发展,沙河原水受生活污水、工业废水、农田排灌废水及垃圾等污染的程度呈加重趋势,若遇暴雨则污染更为明显。根据1997年—2000年的监测结果,原水色度一般为12~45 倍(少数时间超过40 倍),CODMn最高为10.28 mg/L,BOD最高达27.35 mg/L,NH3-N一般为0.5 mg/L(暴雨时曾高达2.56 mg/L,在短时间内给水厂生产造成了一定困难)。 复合生物活性滤料滤池是由活性和惰性滤料复合构成滤床,在保持滤池去除悬浮物功能的基础上强化滤池去除有机物的能力,其中的活性滤料由极性和非极性滤料复合构成,用以提高滤池吸附、去除有机物的能力[1]。该滤池还采用空气充氧,是一种生物滤池。
1 试验内容
该试验主要研究复合生物活性滤料滤池的挂膜情况和在正常运行下对COD和NH3-N等污染物的去除情况以及滤后水消毒后的水质是否能够满足国家《生活饮用水卫生标准》、Ames试验结果是否比现有工艺有明显改善。 试验在五水厂进行,复合生物活性滤料滤池的待滤水来自该厂的机械加速澄清池,滤后水则进入移动罩滤池的清水渠,其整体流程如下:
|