建筑给排水论文 摘要:进行了直接超滤和混凝—超滤组合工艺对腐殖酸的建筑给排水论文去除效果和膜污染状况的建筑给排水论文试验。结果表明,超滤前加混凝预处理对腐殖酸的DOC和UV254的去除率分别从28%、40%提高到53%、78%。同时高效液相色谱(HPLC)分析表明,混凝—超滤组合工艺对分子质量<6000u的有机物的去除率提高幅度更为显著。混凝—超滤组合工艺的最佳pH值条件为pH=7,通过卷扫混凝使小分子有机物结合成微絮体,降低了膜孔污染,使超滤保持了较高的渗透通量。 关键词:混凝 超滤 卷扫 渗透通量
中图分类号:TU991 文献标识码:A 文章编号: 1000-4602(2002)03-0018-05
Experimental Study on the Humic Acid Removal by Means ofCoagulation-Ultrafilt ration WANG Xiaochang,WANG Jin (School of Environmental and Municipal Engineering,Xi‘an University of Arc hitectural Technology,Xi‘an 710055,China)
Abstract:Experiment was made on the humic acid removal and the membrane fouling by means of ultrafiltration with and without coagulation pretreatment.The results show th at use of coagulation ahead of ultrafiltration for pretreatment of humic acid results in a rise in removal rate ofDOC and UV254 from 28% and 40 % to 53% and 78% respectively.In the meantime,it is shown by high performance l iquid chromatographic (HPLC) analysis that the coagulation-ultrafiltration proce ss has significant improvement of removal rate of organic matters with molecular weight<6000u.The optimal pH value for coagulation-ultrafiltration process i s 7,and sweeping coagulation can make small molecular organic matter agglomerate d into microflocs,which results in the reduction of membrane pore fouling and makes the ultrafiltration kept at high permeation flux. Keywords:coagulation;ultrafiltration;sweeping;permeation flux
为了提高超滤对水中天然有机物的去除效果并减轻膜污染,一种可行的方法就是通过各种预处理来改变水中污染物的表面性质和存在形态[1~4]。其中混凝预处理由于简便、易行,与超滤组合去除水中污染物的工艺受到了关注,但是对于该组合工艺的特点和控制方法的研究尚不深入(尤其是去除机理方面),许多问题还不明确。为此,以水中天然有机物的代表性物质——腐殖酸为研究对象,利用国产超滤膜进行了混凝—超滤组合工艺的试验。
1 试验内容
1.1 试验装置 试验装置如图1所示。 超滤组件采用截留分子质量为1×105u的国产中空纤维膜,材质为聚丙烯腈(PAN),加压方式为内压式,处理能力为109L/(m2·h)。

1.2 试验方法 原水用从某湖泊底泥中提取的天然腐殖酸经0.45μm滤膜去除水中悬浮性杂质后的原液配制,其溶解性有机碳(DOC)浓度为5mg/L。采用两种工艺:一是原水直接超滤,二是混凝—超滤组合,混凝剂为精制硫酸铝[Al2(SO4)3·18H2O],投药量为3.5mg/L(以铝离子浓度计),采用泵前投药、水泵混合和管式混合器混凝,停留时间为1min左右,G值为10s-1(属于微絮凝)。为了比较不同pH值对处理效果的影响,加药后水的pH值控制在5和7两种条件。
|