| | | 固定化生物活性炭处理低浓度甲醇废水的工程应用
| | 给水排水毕业论文 摘要:本文在小试和中试研究的给水排水毕业论文基础上提出了固定化生物活性炭处理低浓度甲醇废水并回用的给水排水毕业论文工艺路线,完成了工程设计和建设。工程运行结果表明,该系统可将混合液的COD从40mg/L降至12mg/L以下,对甲醇的去除率达到93.6%~100%,其出水水质可以满足回用到锅炉脱盐水系统进水的水质要求。 关键词:工艺冷凝液 尿素水解水 低浓度甲醇废水 固定化生物活性炭
Applation of Immobilized Biological Activated Carbon to Methanol-loaden Wastewater Treatment Li WeiguangShi WenxinZhao Qingliang (School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin, China, 150090 ) Abstract:Based on the previous studies, the technique of immobilized biological activated carbon for treatment and reclamation was carried out. It was found that the project of treatment and reclamation could reduce COD from 40 mg/L to 12 mg/L and the removal efficiency of methanol was 93.6%~100%.The effluence of this project can meet the standard of desalter system. Keywords: Process liquor condensate; Urea hydrolyzing wastewater; Methanol-loaden Wastewate;Immobilized Biological Activated Carbon 0 概述 我国的氮肥厂每天排放出数十万吨工艺冷凝液和尿素水解水,这些仅受轻微污染的废水是潜力巨大的资源,具有很好的回收利用价值。分析表明氮肥厂工艺冷凝液和尿素水解水中最主要的污染物为低浓度甲醇,因而去除低浓度甲醇成为这类废水回收利用的关键。本文在小试[1]和中试[2]研究的基础上设计了人工固定化生物活性炭技术处理低浓度甲醇废水处理并回用的工艺流程,为废水资源化提供了一种新途径。 1 .工艺冷凝液和尿素水解水的水量与水质 中国石油天然气股份有限公司大庆石化分公司化肥厂是一个年产合成氨30×104吨、尿素48×104吨的大型氮肥厂,排放的工艺冷凝液和尿素水解水仅受轻度污染,年排放量约为130×104m3,其水质情况如表1所示。 表1工艺冷凝液和尿素水解水的水质情况
项目 工艺冷凝液 尿素水解水
甲醇(mg/L) 74 -
COD(mg/L) 80 20
NH3(mg/L) 4.7 -
pH值 6.0 9.0
尿素(mg/L) - 5.0
2.1工艺流程 大庆石化公司化肥厂低浓度甲醇废水处理和回用工程的工艺流程如图1所示。来自生产车间的工艺冷凝液和尿素水解水混合后,其水温较高,大约在50~60℃之间,为了给后续的单元提供更好的工作条件,设计中采用换热器对混合液进行冷却。
| | | |
| | | | <<<<<全文未完>>>>> 全文字数约2586字 | |
| | |
| |
|